isaleCAD

Quick Link

Suggestions

Applications

More third-party add-ons are available for better industry-specific application.

Download

Language

Operating System

Platform

Developer

AnkiSOFT

Website

Learn More

isaleCAD

Applications 2021-03-18 13:55:00 1818
isaleCAD WATER TRANSMISSION LINE DESIGN SOFTWARE
For Drawing/Modelling/Planning/Design/Analyze
AnkiSOFT Software developes software to design infrastructure projects. isaleCAD has been
developed for water transmission line design. It is for
drawing/modelling/planning/design/analyze the water transmission line. The software works
under ZWCAD.
AnkiSOFT Software isaleCAD – Water Transmission Line Design Software - Menu of the
Software
 
DRAWING the NETWORK
It is possible to arrange the drawing style by using STYLE MANAGER, so you can use different
drawing style in different projects.
OPEN LAYER command can open all the necessary layers that the software needs.
You can define/draw/edit/delete/move Station nodes/Keeper nodes (SK), can change some/all
properties of SKs. The software will write; SKno and the ground elevation for each SK on the
drawing.
You can find any SK by searching the SKno, can change the location of SKno, can renumber
some/all SKnos from a specified number.
You can define/draw/edit/delete pipes, can change the direction of pipes, can change some/all
properties of pipes.
You can define/draw/delete air-releasing-valve/water-drain-valve to any SK. You can renumber
them.
Water Transmission Line - Line Model
 
ERROR CHECKING
You can check weather there is any mistake in the network model. You can find and you can
correct them.
Such as; same SKnos, pipe connections from/to SKs.
HYDRAULIC DESIGN
During design works; all the information on the drawing will be send to calculation, the
calculation software will do hydraulic calculations, then all the calculated information will be
send back to the drawing to show the final situation.
You can repeat this process, until you reached to the situation that you want.
DESIGN CRITERION
You can define;
Water supply point can be; pump-station, embedded-reservoir, elevated-reservoir or
pressure-decreasing-valve
Water destination point can be; embedded-reservoir, elevated-reservoir, pressure
decreasing-valve, network enterance node or water-drain-valve
Profile drawing height
You can decide air-releasing-valve/water-drain-valve, or software will decide them itself, or
software and you can decide together
The software will decide vertical curve fittings automatically
If the pipe slope is greater than or equal to 30%, software will add backfill-supporting-wall
automatically
Curve angles can be in degree/grad
Pressure calculations can be according to pipe bottom elevation or pipe center elevation
The output is in DXF file format
For each Type-DIAMETER; type-name, material (concrete, reinforced concrete, PVC, ACB,
Steel, Cast iron, Ductile iron, HDPE, CTP, ...), allowable pressure, wall thickness, inner
diameter, pipe discharge, design formula (William-Hazen, Ludin, ...), "C" values for the
formula, outer diameter and basement layer thickness.
DESIGN CALCULATION TABLES
Hydraulic calculations are in the form of tables and recorded in a text file. In the first table;
SKno
Distance from the beginning
Ground elevation
Pipe elevation
Total JL
Total local head loss (LK)
Total JL+LK
Piesometric elevation
Pressure during operation
Maximum pressure
Minimum pressure.
In the second table;
SKno
Air-releasing-valve/water-drain-valve name
Angle of horizontal curve
Angle of vertical curve
Angle of 3D curve.
PROFILE
The information on the profile is;
Excavation depth
SKno
Ground elevation
Pipe center/bottom elevation
Distance between SKs
Distance from the beginning
Pipe diameter and material type
Slope
Direction on the plan. All of them will be prepared automatically.
Water Transmission Line - Profile (Pressurized Line)
Water Transmission Line - Profile (Gravity Line)
Water Transmission Line - Profile (Gravity Line)
SCHEMATICAL PROFILE
The information on the profile is;
Maximum pressure line
Piesometric line
Static line
Minimum pressure line
SKno
Pipe center/bottom elevation
Distance between SKs
Distance from the beginning
Pressure during operation
Maximum and minimum pressure during water hammer
Static pressure
Pipe diameter and material type. All of them will be prepared automatically.
Water Transmission Line - Schematic Profile (Pressurized Line)
Water Transmission Line - Schematic Profile (Gravity Line)
 
INFORMATION TRANSFER
You can transfer easily all the network information to another drawing/computer, or vice versa.
GENERAL
There is no limit to the number of SKs and pipes.
There is no limit to the number of pipe diameters and pipe materials.
It is possible to have more than one transmission line on the same drawing. There is no limit
to the number of transmission line.
During design works; the software can show the logical mistakes of the transmission line to
the user to correct them.
On the schematic profile; you can see the SKs having pressure less than minimum
operational-pressure and having pressure above the maximum-static-pressure.
You can renumber SK numbers automatically.
All calculations are in a text file, in the form of tables. You can open, you can copy, you can
print directly at any time.
You can use our software commands with ZWCAD commands too.
 
UPGRADE HISTORY
JANUARY.2018
AutoCAD 2018 x64, ZWCAD 2018 x64
Windows7 x64, Windows8.0 x64, Windows8.1 x64, Windows10 x64
Sentinel HASP HL Pro Driverless, Sentinel-LDK_SDK_7.6 x64
MAY.2017
AutoCAD 2017 x64, ZWCAD+ 2015 x64
Windows7 x64, Windows8.0 x64, Windows8.1 x64, Windows10 x64
Sentinel HASP HL MaxMicro Driverless, Sentinel-LDK_SDK_7.1 x64
JANUARY.2015
AutoCAD 2015 x64, ZWCAD+ 2015 x64
Windows7 x64, Windows8.0 x64, Windows8.1 x64
Sentinel HASP HL MaxMicro Driverless, Sentinel-LDK_SDK_7.1 x64
JANUARY.2013
AutoCAD 2013 x64
Windows7 x64
Sentinel HASP HL Max, Sentinel-HASP_SDK_5.12 x64
JUNE.2012
Windows7 x64, Windows8.0 x64, Windows8.1 x64
Sentinel HASP HL Max, Sentinel-HASP_SDK_5.12 x64
JANUARY.2012
Windows7 x32
Sentinel HASP HL Max, Sentinel-HASP_SDK_5.12 x64
JANUARY.2010
WindowsXP x32
Aladdin HASP HL Max, Ver1.1 x32
JANUARY.2009
WindowsXP x32
Aladdin HASP HL Max, Ver1.1 x32
JANUARY.2003
WindowsXP x32
JANUARY.1999
Windows98
JANUARY.1997
ACAD 14
Windows98
JANUARY.1988
MSDOS